RENEGADE™ All Purpose Ready Mixed Joint Compound
Renegade Ready Mixed Joint Compound is a non-asbestos, ready-to-apply formulation for embedding drywall tape reinforcement, fasteners, corner beads and drywall trims over wallboard. Ready Mixed Joint Compound may also be used for filling, leveling and finishing coats, skim-coating entire wallboard surfaces, and applying simple textures.
ADVANTAGES
LOW SHRINKAGE AND CRACK RESISTANT:
Compound is ideal for heavy fill because of its low shrinkage, excellent adhesion, and crack resistance.
CONSISTENT PRODUCT TIME AFTER TIME:
Satisfied customers continually report that Renegade Joint Compound is highly consistent from batch to batch. This is achieved through precise internal procedures and quality control.
PRECAUTIONS:
If dry-sanding or otherwise working in a dusty environment containing this material, ventilate or use a dust collector. It is also recommended that eye protection and a NIOSH-approved respirator be worn. Wet sanding or sponging finished joints is recommended to avoid creating dust.
WARRANTY:
Job conditions and methods of application, such as temperature, humidity, and over-thinning, are beyond the control of SWP Inc. Its warranties of fitness and merchantability, as well as any other warranties expressed or implied, shall be effective if this product is applied according to SWP Inc. directions and specifications. Maximum liability shall be limited to the replacement of material only.
RENEGADE Southern Wall Products Incorporated
Customer Service: 1-800-554-9255
1825 Fellowship Rd
Tucker, Georgia 30084
770-621-3065
Product Specifications and Details
Product Data
MATERIAL:
Non-asbestos, ready-mixed formulation
TYPE:
Hand or mechanical application
PRODUCT SENSITIVITY:
Protect from freezing or overheating
COVERAGE:
Approximately 8.7 gallons per 1000 square feet of gypsum board (depending on job conditions, methods of application, and tools used)
COMPLIANCE WITH STANDARDS:
Meets ASTM designation C-475
STORAGE:
Good storage conditions will allow up to a 12-month shelf life. For best product life, avoid excessive heat, direct sunlight, or freezing conditions, which can cause thinning and/or premature aging of the product.
3.5 Gallon Box
Architectural Specifications
PART 1: GENERAL
1.01 Scope Specify to meet project requirements.
1.02 Qualifications Southern Wall Products, Inc. and approved manufacturers shall manufacture all Gypsum Wallboard finishing materials. The materials shall be installed in accordance with the Association of Wall and Ceiling Industries’ “Recommended Levels of Gypsum Board Finish.”
1.03 Delivery and Storage Store in an enclosed shelter in the original unopened packages. Protect from temperatures below freezing and over 120°F.
1.04 Project Conditions
A. Install interior gypsum wallboard finishing materials only after the building is enclosed.
B. Ventilation:
- Provide ventilation during and following joint treatment application.
- Use temporary air circulators in enclosed areas lacking natural ventilation.
- Allow additional drying time between coats of joint treatment under slow drying conditions.
- Protect installed materials from drafts during hot, dry weather.
C. Temperature:
Maintain a minimum surface, mix, and air temperature of 50°F – 100°F until all joints have dried completely.
PART II: PRODUCTS
2.01 Materials
A. Joint Reinforcement – Reinforcing Tapes
B. Joint Treatment
Renogade™ Ready Mixed Joint Compounds
PART III: EXECUTION
3.01 Installation Use all products in accordance with Southern Wall Products’ printed package instructions.
3.02 Application – Joint Compound
(Each level and specific application to be determined in accordance with recommended Levels of Gypsum Board Finish as developed by AWCI)
A. Level 1 Intended for plenum areas above ceilings, areas where assembly is concealed by final construction, smoke barriers, and separation walls in attics.
B. Level 2 Intended for water-resistant gypsum board for tile substrate, garages, warehouses, and other areas where appearance is not of primary concern.
C. Level 3 Intended for appearance areas receiving heavy or medium texture finishes or where heavy grade wallcoverings are to be applied as final finish.
D. Level 4 Intended for appearance areas receiving flat paints, light texture finishes, or light or medium weight wallcovering.
E. Level 5 Intended for appearance areas receiving flat, low-luster, semi-gloss, gloss, or enamel finish paints or coatings, light texture finishes, light or medium weight wallcovering, un-backed vinyl wallcoverings, or severe light conditions.